maxTURBOMATIC (MAX)

TURBOMATIC MAX is most commonly used in the applications where the climate conditions can be extreme, and when high power and/or continuous 24/7 heating of the concrete aggregates and/or water is needed.

Typical applications

  • Large scale concrete production e.g. precasters and production units in extreme climate conditions

Main functions

  • Aggregate heating with TURBOgas or –steam
  • Generation of warm dosing water

Heating options

  • Heating of the concrete batching plant production facilities
  • Generation of warm wash and utility water
  • Supply of warm water for filling the truck mixer saddle tank
  • Heating of other associated facilities e.g. offices, laboratories etc.
  • Curing of concrete products

maxTURBOMATIC models

 

PME-MAX 750PME-MAX 1000PME-MAX 1250PME-MAX 1500PME-MAX 2000PME-MAX 2500

Capacity

750 kW1000 kW1250 kW1500 kW2000 kW2500 kW
Aggregates
75…750 kW

Water
0…675 kW
Aggregates
100…1000 kW

Water
0…900 kW
Aggregates
125…1250 kW

Water
0…1125 kW
Aggregates
150…1500 kW

Water
0…1350 kW
Aggregates
200…2000 kW

Water
0…1800 kW
Aggregates
250…2500 kW

Water
0…2250 kW

Powered with

Light fuel oil, biodiesel
75 l/h100 l/h125 l/h150 l/h200 l/h250 l/h
Natural gas
75 m³n/h100 m³n/h125 m³n/h150 m³n/h200 m³n/h250 m³n/h
Natural gas pressure min 0,8 bar (g)
Propane
30 m³n/h39 m³n/h50 m³n/h59 m³n/h78 m³n/h100 m³n/h

Options

  • Fully integrated oil tank located inside TURBOcontainer (oil tank volume 4 000 l/20’ container or 10 000 l/40’ container); separated with firewall and equipped with all necessary safety etc. accessories
  • Combi-burner for dual fuel operation: light fuel oil or natural gas
  • Gas-burner for propane or other gaseous fuels
NOTE! Actual fuel consumption is significantly lower than rated consumption at max. load

Structure / Layout

TURBOcontainer

  • Thermally insulated, for outdoor usage
  • Side door for easy access
  • Standard 20’ (L 6050 x W 2438 x H 2592 mm)* or standard 40’ (L 12192 x W 2438 x H 2592 mm)